LogoLogo
HomeCodeEmail Support
  • VotingWorks
  • Central System Setup
    • VxAdmin Hardware Setup
    • Pre-Election Setup Checklist
    • VxDesign
    • Configure VxAdmin
    • Smartcards and User Roles
    • Save Ballot Package
    • VxCentralScan Hardware Setup
    • Configure VxCentralScan
    • Unlocking/Locking Hardware
    • Setting Date & Time
    • USB Formatting
    • Demo Election Definition
  • VxScan
    • Configure VxScan
    • Election Manager Settings
    • Additional Poll Worker Actions
    • VxScan Error Messages
    • System Administrator Functions
  • L&A Testing
    • L&A Overview
    • L&A Cleanup
  • Poll Worker Guides
    • Poll Worker Checklist
    • VxScan Setup
    • Opening Polls
    • Assisting Voters
    • Closing Polls
    • Packing Up VxScan
  • Election Night Admin Guides
    • Election Night Checklist
    • Central Scanning
    • Tally Results
    • Write-In Adjudication
    • Manual Results
  • After Election Night
    • Final Post-Election Checklist
    • Mark Results as Official
    • Retaining & Removing Election Files
  • Reference
    • Hardware Specifications
    • Printer FAQs
    • Supply List
Powered by GitBook
On this page
  • Remove CVR Files from VxAdmin
  • Toggle VxCentralScan to Official Ballot Mode
  • Toggle VxScan to Official Ballot Mode
  1. L&A Testing

L&A Cleanup

PreviousL&A OverviewNextPoll Worker Checklist

Last updated 1 year ago

Remove CVR Files from VxAdmin

When L&A is complete, select Tally from the side menu, then select Remove CVR Files to clear VxAdmin of CVRs in preparation for election day. Confirm by selecting Remove CVR Files in the popup confirmation screen.

Toggle VxCentralScan to Official Ballot Mode

If you used Test Ballot Mode to conduct your L&A be sure to Toggle to Official Ballot Mode in VxCentralScan. To change modes, select Admin and then Toggle to Official Ballot Mode.

If you used Official Ballot Mode to conduct your L&A, select Delete Ballot Data to erase all test batches of ballots.

Toggle VxScan to Official Ballot Mode

If you used Test Ballot Mode to conduct your L&A be sure to put VxScan into Official Ballot Mode. Insert the Election Manager Card into VxScan to show the Configuration Screen, and select Official Ballot Mode.

If you used Official Ballot Mode to conduct your L&A, simply toggle to Test Ballot Mode and back to Official Ballot Mode to reset VxScan for Election Day.

Remove the Election Manager Card, and confirm that the VxScan is in official ballot mode by ensuring there is no orange Test Ballot Mode banner and Polls Closed is displayed.

Note: a USB drive is required to use VxScan on Election Day. After testing, you may reinsert the USB drive tested or a new USB drive into the USB slot and seal the left hand door until a poll worker accesses the machine on Election Day.