Precinct (VxScan + VxMark) Checklist
Last updated
Last updated
This Precinct Checklist is appropriate for any precinct using both VxMark as an accessible ballot-marking device and VxScan as a precinct scanner. The equipment is best tested together, as they need matching configurations and will be used together at the precinct. At this point in logic and accuracy testing, both VxScan and VxMark should already be configured.
Insert a new USB drive
Confirm Election, Election ID, Date, Time, and Precinct (EM Card)
Select Calibrate Scanner
and insert a blank sheet of paper (EM Card)
Confirm VxScan is in Testing Mode (EM Card)
Open polls (Poll Worker Card)
Confirm printer has plenty of paper
Confirm Election, Election ID, Date, Time, and Precinct
Confirm VxMark is in Testing Mode
Open polls and print Open Polls Report from VxScan to serve as the Zero Report (Poll Worker Card)
Confirm Opened Polls Report is all zeros
Confirm all expected ballot styles show up as options at top of screen
Confirm all Poll Worker Cards work
Run the Ballot Style Sub-Checklist for each ballot style
For one of the ballot styles selected at random, confirm that the entire ballot can be filled out and printed using only the audio track over headphones and the accessible controller (do not scan this ballot)
Scan all ballots from the precinct's L&A Package
Pre-voted VxMark test ballots (do not scan your own test votes from VxMark)
Pre-voted hand-marked test ballots
The blank ballot
Confirm it is rejected & select Cast Ballot as Is
The overvoted ballot
Confirm it is rejected & select Cast Ballot as Is
Close polls (Poll Worker Card)
Switch to Live Election Mode
(EM Card)
Print Polls Closed Report (Poll Worker Card)
Confirm Polls Closed Report matches Test Deck Tally
Switch to Live Election Mode
(EM Card)
Remove ballot bag
Remove ballots from ballot bag
Set aside blank piece of paper - you will not need this later
Set aside blank and overvoted ballots - you will not need this later
Set aside test deck ballots - you will need this later
Open metal enclosure
Remove USB drive and set aside
Validate results from the USB drives at VxAdmin.
Verify neither VxScan nor VxMark has an orange testing banner on the screen
Insert tested USB drive into VxScan
Close metal enclosure
Close Ballot Bag Main Opening
Seal Ballot Bag Main Opening
Place Ballot Bag into VxScan
Seal Ballot Bag in place
Flap side 1
Flap side 2
Pack Up VxScan according to Poll Worker Instructions
Zip ballot entry flap and top
Seal ballot entry flap and top together
Pack Up VxMark according to Poll Worker Instructions
Seal VxMark
Seal Location | Seal Color | Number |
---|---|---|
Name:
Date:
Ballot Box Main Opening
Ballot Box Flap 1
Ballot Box Flap 2
VxScan
VxMark